MAINTENANCE > SET> CONVEY
PSI
BAR
CONVEY
47
3.24
TIE PRESSURE RANGE
1M
47 - 52
3.2 - 3.6
1.5M
37 - 42
2.6 - 2.9
BACK
10
POSSIBLE CAUSE:
This error message appears if the PDM4.0 Dispenser internal regulator was adjusted
incorrectly, or the dispenser piston is not fully shifting.
CORRECTIVE ACTION:
Press the
“Silence” icon
to turn the alarm signal "off", and resume operation. If the
message remains, the system will not operate. Write down the message and notify the maintenance department.
PREVENTION:
Never adjust the PDM4.0 Dispenser internal regulator. Follow the maintenance schedule for
greasing the piston.
ERROR 15 - Internal regulator incorrectly set, high
ERROR 15 > INTERNAL REG.
INCORRECTLY SET, HIGH
AIR BURST
LOAD
MAINTENANCE
SILENCE
HELP
BACK
83
Error Screen
MAINTENANCE > SET> CONVEY
PSI
BAR
CONVEY
47
3.24
TIE PRESSURE RANGE
1M
47 - 52
3.2 - 3.6
1.5M
37 - 42
2.6 - 2.9
BACK
10