© Panduit Corp. 2022
FS132D
4
Rev 05
Performing Terminations
Step 1:
Set up the tool by selecting the
correct launch cord, cradle, and tool
settings. The launch cord and cradle
table is displayed below. Make sure to
‘Save’
the selections.
Note:
the image to the right displays the set up for a singlemode LC
termination. Options may appear differently depending on firmware
version on the tool.
Connector Type
Launch Cord Part
Number
Launch Cord
Color
Cradle Part
Number
Cradle Color
LC Singlemode
(e.g. FLCSSCBUY)
FOLPC-1.25SM
Yellow
FLCC2
Black
LC Multimode
[all grades]
FOLPC-1.25MM
Orange
(e.g. FLCSMCXAQY, FLCSMC6EIY)
SC Singlemode
(e.g. FSC2SCBU)
FOLPC-2.5SM
Yellow
FSCC2
Gray
ST Singlemode
(e.g. FST2SCBU)
FSTC2
Gray with black
components
SC Multimode
[all grades]
FOLPC-2.5MM
Orange
FSCC2
Gray
(e.g. FSC2MCXAQ, FSC2MC6EI)
FSTC2
Gray with black
components
ST Multimode
[all grades]
(e.g. FST2MCXAQ, FST2MC6EI)
Tip:
When snapping the LC launch cord into the cradle it is vital to make sure the circular aperture on the metal
adapter faces down, towards the tool. Failure to align the adapter properly will create difficulty with the process.
Also, ensure that the metal adapter is firmly tightened onto the cord before installing onto the cradle.
Tip:
When terminating ST connectors, the launch cord must be inserted
directly onto the connector’s ferrule
. If it is
not fully pushed onto the connector, the tool may not recognize the connector in the following steps.