Panduit OPTICAM 2 Quick Start Manual Download Page 10

© Panduit Corp. 2022 

 

FS132D 

Rev 05 

 

 

 
Step 12: 

Remove the connector from 

the tool and replace the dust cap. Slide 
the boot up the fiber and push it onto 
the rear of the connector. Note that 
the 900-micron boot is held in place by 
tension, you do not need to thread it 
onto the connector. For SC connectors, 
apply the outer housing. 
 

Tip

: When doing ST terminations remember to remove the 

launch cord from the connector before trying to remove the 
connector from the cradle. 

 

 

 

 

 

 

 

Note:

 The full instruction manual for OptiCam® terminations includes additional instructions for 250-micron fiber 

with build-up tubing, termination onto 1.6/2.0mm and 3.0mm jacketed cable, duplexing connectors, and more. 
Please refer to 

FS133: OptiCam® 2 Termination Tool User Manual

 for further details, available on panduit.com.  

Troubleshooting Tips: 

1.

 

Make sure the tool is using the most current version of firmware, as this will often include improvements 

for the best overall user experience. A USB to Micro USB data cord (e.g. FOCTT2CORD) is required for this 

process. 

2.

 

Make sure the tool is set up properly with the right cord, right cradle, right connector, and right settings 

to match the intended termination. 

3.

 

Always replace the batteries with size AA Energizer L91 batteries or similar. Alkaline batteries are not 

designed for complex electronic devices and will be consumed very rapidly. The tool can also be powered 

directly via a Micro USB cord to save battery life. The tool will not charge batteries.  

4.

 

Make sure to properly clean the launch cord every 50 terminations to ensure an optimal function of the 

tool and user experience. Dirty/damaged launch cords are a leading cause of user difficulty. 

5.

 

Make sure to do a good, 7mm cleave on the field fiber. Cleave lengths greater than +/- 1mm off will 

create an increasingly more difficult termination process. Proper use of the cleaver is vital, as a poor 

cleave is a leading cause of user difficulty. 

6.

 

Use the help menu on the tool when an error message appears. If further assistance is needed, contact 

Panduit’s Technical Support team

. Most issues are simple to diagnose and remediate. 

7.

 

The OptiCam 2 tool is not recommended for use outdoors. Sunlight will oversaturate the camera aperture 

and disrupt the tool’s function. The 

included magnetic hood (FCCVR2) may help in some situations. 

Summary of Contents for OPTICAM 2

Page 1: ...Panduit Corp 2022 FS132D OptiCam 2 Quick Start Guide...

Page 2: ...ed at a reduced rate battery life Tool can also be powered without batteries through the power data 5 VDC 1 amp max port on the side of the tool Rated Battery Life Approximately 8 hours continuous use...

Page 3: ...de batteries or similar for optimal tool performance Step 2 Remove the protective film cover from the camera aperture and LCD screen Step 3 Power up the tool by clicking once on the center of the sele...

Page 4: ...found at Panduit com Support Download Center Software Firmware Printers OptiCam 2 Termination Tool Battery Power Indicator Bluetooth Icon where applicable Connector Icon matches settings Cancel Opera...

Page 5: ...ode e g FSC2SCBU FOLPC 2 5SM Yellow FSCC2 Gray ST Singlemode e g FST2SCBU FSTC2 Gray with black components SC Multimode all grades FOLPC 2 5MM Orange FSCC2 Gray e g FSC2MCXAQ FSC2MC6EI FSTC2 Gray with...

Page 6: ...adapter and cradle Tip If the tube is protruding from the rear of an LC connector it is not properly seated in the adapter Rotate the connector slightly until it can be locked in without the insertio...

Page 7: ...y wipe and approved cleaning solution Note DO NOT use pre moistened wipes Note Observe appropriate fiber safety precautions Step 7 Cleave the bare fiber to 7mm Tip You can verify the cleave length usi...

Page 8: ...go from the Load Connector screen to the Background Test screen Note If the tool presents a Cleaning Required or Check Failed message follow the troubleshooting steps on the tool or watch the trouble...

Page 9: ...e connector style ST Rotate the black cam barrel s fin until it fully stops Step 11 Click the selector switch once quickly do not hold it down This will perform the Insertion Loss IL calculation If th...

Page 10: ...l is set up properly with the right cord right cradle right connector and right settings to match the intended termination 3 Always replace the batteries with size AA Energizer L91 batteries or simila...

Reviews: