12
7) GAS SUPPLY
Before installing the product, make sure that data
on the label located on the inner part of the box,
meet specifications of the gas network.
On the label, which is given in the manual, and on
the label, which is located on the inner part of the
box, data for product regulation are given: gas
type and operating pressure.
If gas is supplied via pipeline,
then the product shall
be attached to the gas supply device
:
●
Using rigid steel pipe, according to the applicable
standards, connections shall be performed with
threaded fittings as per EN 10226
.
●Using copper pipe according to the applicable
standards, connection shall be performed with fittings
with mechanical seal as per the applicable standards.
●Using flexible pipe made of stainless steel with solid
walls, according to the applicable standards, with
length of 2 meters maximum and with sealing gasket
as per the applicable standards.
This pipe shall be
installed so that it could touch the moving parts of the
built-
in module (for example, boxes) and don’t
intersect sections, in which any objects can be
arranged.
If gas is supplied directly from cylinder,
then the
product shall be equipped with pressure controller as
per the applicable standards and shall be connected
as follows:
● Using copper pipe according to the applicable
standards, connection shall be performed with fittings
with mechanical seal as per the applicable standards.
● Using flexible pipe made of stainless steel with solid
walls, according to the applicable standards, with
length of 2 meters maximum and with sealing gasket
as per the applicable standards. This pipe shall be
installed so that it could touch the moving parts of the
built-in module (for example, boxes) and d
on’t
intersect sections, in which any objects can be
arranged.
In order to simplify connection of the
pressure controller installed on the cylinder with
connection fitting, it is recommended to install special
adapter on the flexible pipe.
Adapter of such a type can be easily purchased in
the shop.
Upon connection make sure in its complete tightness
using soap solution, use of flame during check shall be
prohibited
.
WARNING:
-
You should remember that gas inlet fitting of the
product is threaded,
1/2”, taper, with male screw
and meet EN 10226.
The product corresponds to the provisions of
additional legal regulations of EU directive:
- Regulation (UE) 2016/426
Moreover, walls and surfaces, which adjoin and
enclose the cooktop, shall withstand temperature
of 90°C.
INSTALLATION