INOXPAN S.L.
EN - 77
7.4. ELECTRONIC PANEL WITH INTENSIVE 3i
MAINTENANCE FUNCTIONS:
• CLEAN AIR:
To preserve air quality--> push Timer button
for 3'' with hood off. The hood turns on at first speed
for 10' per hour, while the function is activated, the power
and timer
symbols flash.
Push any button to disable the function except the lighting button
.
• FILTER SATURATION ALARM:
-
MESH FILTERS:
Light button LED
flashes every 30h of hood operation: the anti-grease filter shall be
cleaned.
To reset the hood when it is off push light button
for 3’’.
-
ACTIVE CARBON FILTERS (FCA):
On/off button LED
flashes every 120h of hood operation: the anti-odor filter shall be
replaced (FCA) (filter version).
To reset the hood when it is off push light button
for 3’’.
SHORT PRESSION
(briefly and firmly for 1 second):
Motor
ON
at first speed.
LONG PRESSION
(keep a few seconds):
OFF
, engine off = Press the symbol extensively and firmly for about 3 seconds.
SHORT PRESSION
: Motor at second speed.
SHORT PRESSION
: Motor at third speed.
LONG PRESSION
(keep a few seconds): intensive speed(4ª) for 7’
(at the end of
this time, the system will return to the speed set previously).
TIMER. Push this button to set up the timer of 5 minutes. After 5 minutes the
cookerhood will be switched off automatically (motor and lighting). When the timer
is activated the LED flashes.
The timer can not be activated for intensive speed "i"(4ª).
Push This button to switch on/offthe light.
For proper operation, keep the Touch Control glass clean and dry. If there is dirt on the Touch Control
glass, it may fail or not respond adequately to the commands.