![background image](http://html2.mh-extra.com/html/panasonic/wvnp1000-network-camera/wvnp1000-network-camera_operating-instructions-manual_3854926034.webp)
34
Configure the settings relating to Panasonic alarm protocol
[Panasonic alarm protocol setup]
Click the [Notification] tab on the "Alarm setup" page. (
☞
page 28)
The settings relating to Panasonic alarm protocol can be configured on this page.
[Panasonic alarm protocol]
Select "ON" or "OFF" to determine whether or not to
notify of an alarm occurrence by Panasonic alarm proto-
col when an alarm is detected.
Default:
OFF
[Destination port]
Select a destination port of the Panasonic alarm proto-
col from the following.
Available port number:
1 - 65535
Default:
1818
[Retry times]
Select a retry time of Panasonic alarm protocol.
Available retry times:
1 - 30
Default:
2
[IP address]
Enter the destination IP address of the Panasonic alarm
protocol from the following. Up to 8 destination address-
es can be registered.
To notify by Panasonic alarm protocol, check the
"Notification setup" checkbox respective to the desired
IP address. To delete the registered IP address, click
the [DEL] button respective to the desired IP address.