332
DP-C405/C305/C265
FEB 2008
Ver. 1.1
E3-33 Toner Cartridge
Drive Motor
Rotation (Y)
The rotation of the
Toner Cartridge Drive
Motor (Y) is not being
detected within a
predetermined time.
Toner
Cartridge
Motor
1. Toner Cartridge is jamming.
(Shake the Toner Cartridge briskly to
loosen the contents)
2. Check the Motor connector.
3. Motor is defective.
4. Motor mechanism is defective.
5. Check the EC PCB connector.
6. EC PCB is defective. (
Check F8 for E3-
35,36 F9 for E3-33,34
)
7. Motor mechanism is defective.
E3-34 Toner Cartridge
Drive Motor
Rotation (M)
The rotation of the
Toner Cartridge Drive
Motor (M) is not being
detected within a
predetermined time.
Toner
Cartridge
Motor
E3-35 Toner Cartridge
Drive Motor
Rotation (C)
The rotation of the
Toner Cartridge Drive
Motor (C) is not being
detected within a
predetermined time.
Toner
Cartridge
Motor
E3-36 Toner Cartridge
Drive Motor
Rotation (BK)
The rotation of the
Toner Cartridge Drive
Motor (BK) is not
being detected within
a predetermined time.
Toner
Cartridge
Motor
E3-37 FTR Motor
Rotation
FTR Motor is not
rotating.
FTR Motor
1. Check the EC PCB connector.
2. EC PCB is defective. (
Check F12
)
3. MOTDRV PCB is defective. (
Check F4 for
E3-37, F1 for E3-38
)
E3-38 STR Motor
Rotation
STR Motor is not
rotating.
STR Motor
E3-63 FTR Cam
Position Error
The FTR Cam
Position Sensor is not
actuating within a
predetermined time.
(FTR Cam Position
detection value is
abnormal)
FTR
1. Check the FTR Cam Motor connector.
2. FTR Cam Motor is defective.
3. Check the MOTDRV PCB connector.
4. MOTDRV PCB is defective. (
Check F4
)
5. Check the FTR Cam Sensor 1 or Sensor
2 connector.
6. FTR Cam Sensor 1 or Sensor 2 is
defective.
7. Check the EC PCB connector.
8. EC PCB is defective. (
Check F12
)
9. FTR Cam Drive mechanism is defective.
E3-64 STR Cam
Position Error
The STR Cam
Position Sensor is not
actuating within a
predetermined time.
(STR Cam Position
detection value is
abnormal)
STR
1. Check the STR Cam Motor connector.
2. STR Cam Motor is defective.
3. Check the MOTDRV PCB connector.
4. MOTDRV PCB is defective. (
Check F1
)
5. Check the STR Cam Sensor 1 or Sensor
2 connector.
6. STR Cam Sensor 1 or Sensor 2 is
defective.
7. Check the EC PCB connector.
8. EC PCB is defective. (
Check F12
)
9. STR Cam Drive mechanism is defective.
E3-65 STR Monitor
Current Read
Error
Not Used
STR
1. STR Connection Error.
2. STR HVPS is abnormal.
3. Check the STR HVPS connector.
E3-66 FTR (Y) Monitor
Voltage Read
Error
Not Used
FTR
1. FTR (Y) Connection Error.
2. FTR (Y) HVPS is abnormal.
3. Check the FTR (Y) HVPS connector.
E3: Development System Error Codes
Code
Function
Contents
Section
Check Points
Summary of Contents for Workio DP-C265
Page 2: ...2 ...
Page 3: ...3 ...
Page 5: ...5 ...
Page 6: ...6 For PB and Other destinations not for PU USA Canada ...
Page 11: ...11 ...
Page 12: ...12 ...
Page 13: ...13 ...
Page 14: ...14 memo ...
Page 94: ...94 FEB 2008 Ver 1 1 DP C405 C305 C265 Color Test Chart 101 P N PJQRC0119Z LDR PJQRC0120Z A3 ...
Page 106: ...106 FEB 2008 Ver 1 1 DP C405 C305 C265 2 20 720K PM Kit DQ M35S72 DQ M32N72 ...
Page 274: ...274 FEB 2008 Ver 1 1 DP C405 C305 C265 LVPS CN6 LVPS CN7 Refer to SCN PC Board ...
Page 275: ...275 FEB 2008 Ver 1 1 DP C405 C305 C265 LVPS CN8 Europe Specification Only ...
Page 278: ...278 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN603 CST PCB CN604 ...
Page 279: ...279 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN605 ...
Page 280: ...280 FEB 2008 Ver 1 1 DP C405 C305 C265 ...
Page 281: ...281 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN606 ...
Page 282: ...282 FEB 2008 Ver 1 1 DP C405 C305 C265 ...
Page 283: ...283 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN607 ...
Page 284: ...284 FEB 2008 Ver 1 1 DP C405 C305 C265 CST PCB CN608 ...
Page 286: ...286 FEB 2008 Ver 1 1 DP C405 C305 C265 TRU PCB CN613 ...
Page 288: ...288 FEB 2008 Ver 1 1 DP C405 C305 C265 RLB PCB CN176 ...
Page 682: ...682 FEB 2008 Ver 1 1 DP C405 C305 C265 memo ...
Page 738: ...738 FEB 2008 Ver 1 1 DP C405 C305 C265 memo ...
Page 808: ...519 E ...