94
95
④
Alarm log display button
The alarm log are displayed on the operation panel of the control screen. Up to 1000 alarm logs are saved.
When more than 1000 logs are filed, the older logs will be overwritten by the newer logs. In this case, the
oldest log is the first to be overwritten.
⑤
Alarm reset button
Cancels the alarm action. If the recording time of emergency recording is set to "Ext.", the emergency recording
will be stopped. Clickable only in the alarm state and emergency recording state.
⑥
Error log display button
The error (trouble) logs are displayed on the operation panel of the control screen. Up to 1000 error logs are
saved. When more than 1000 logs are filed, the older logs will be overwritten by the newer logs. In this
case, the oldest log is the first to be overwritten.
⑦
Error reset button
Cancels the error (trouble) action. Clickable only in the error state.
Sub monitor (monitor for display of live images only)
Important:
• Configuration and operation of the recorder from the sub monitor is not possible.
Live images from the specified cameras can be displayed on 1-screen or 4-screen/9-screen/16-screen/24-screen/
32-screen on the sub monitor. When several cameras are selected on 1-screen or 4-screen/9-screen/16-screen,
camera images will be switched sequentially at the selected switching interval (sequence display). In addition,
camera images can be switched according to the signal input triggered by a terminal alarm. (
☞
Note:
• The date & time and camera also appear on the camera image displayed on the sub monitor, but some
characters may be cut off.
• To display images, it is necessary to select the cameras to be displayed in the setup menu in advance. The
recorder is not configured to display camera images by default.
• Depending on the selected switching interval, a black screen may appear before camera images are dis-
played.
• When the secret view function is selected, the single screen on the main monitor or selected images on a
multiscreen will not be displayed.
• While "1-screen live sequence" is being performed, the secret view images will be skipped (not displayed).
• During 9-screen or 16-screen live sequence operation, the black screen is displayed when the camera
image is switched.
• The image of a camera where an error has occurred will not be displayed.
• The size of displayed images will be fit into the screen regardless of the aspect ratio at the default setting.
When the aspect ratio of the sub monitor (BNC) is 4:3, the vertically long images will be displayed compared
with the images of the sub monitor (HDMI).
• Depending on whether enabling or disabling the re-encoding transmission, the frame rate or the resolution
of camera images on the sub monitor may vary, or the sub monitor may momentarily go black.
[Operation via recorder's main monitor]