78
79
Menu/Tab
Setting item (including those of the
"Advanced setup" menu)
Available range
Default
Remarks
Recording
setup
Advanced
recording
setup
Rate
1 ips, 3 ips, 5 ips, 10 ips, 15 ips,
25 ips, 30 ips, 50 ips, 60 ips
10 ips
◎
Quality
NQ, FQ, SF, XF
FQ
◎
Audio
[Camera]
Off, On, On(G.711)*,
On(AAC-LC)
[Network Microphone]
Off, Cam.1, ..., Cam.32
Off
◎
Schedule
Schedule1, Schedule2, ...,
Schedule16
Schedule1
◎
Event
1 ips, 3 ips, 5 ips, 10 ips,
15 ips, 25 ips, 30 ips, Same
as the basic
Same as the basic
◎
Emergency
1 ips, 3 ips, 5 ips, 10 ips,
15 ips, 25 ips, 30 ips, Same
as the basic
Same as the basic
◎
Referenced recording
days
(Calculated result will be
displayed.)
(Calculated result
will be displayed.)
◎
Event setup
Alarm action
Output duration
0 s, 2 s, 5 s, 10 s, 20 s, 30 s,
1 min, Ext., Rec.
2 s
◎
Buzzer duration
0 s, 2 s, 5 s, 10 s, 20 s, 30 s,
1 min, Ext., Rec.
2 s
◎
Auto reset time
2 s, 5 s, 10 s, 20 s, 30 s,
1 min, 3 min, 5 min, Ext.
Ext.
◎
Message display
Off, On
On
◎
Main monitor action
Off, On, On(ACK/RESET)
Off
◎
Event type
Checked/Not checked
Terminal alarm:
Checked
Camera site alarm:
Checked
Command alarm:
Checked
◎
Display
Ctrl screen, Wide view
Ctrl screen
◎
Advanced
terminal alarm
setup
Mode
Off, Recording only,
Recording & alarm action
Recording & alarm
action
◎
Alarm log
Save, Not save
Save
◎
Setup by terminal
(Recording camera)
Off, Cam.1, ..., Cam.32, All
Camera number
associated with the
terminal number
◎
Setup by terminal
(Preset)
001 - 256, ---
---
◎
Setup by terminal
(Terminal output)
Off, On
On
◎
Setup by terminal
(Terminal input)
N.O., N.C.
N.O.
◎
Advanced
camera site
alarm setup
Mode
Off, Recording only,
Recording & alarm action
Recording & alarm
action
◎
Alarm log
Save, Not save
Save
◎
Setup by camera
(Recording camera)
Off, Cam.1, ..., Cam.32
Camera number
◎
Setup by camera
(Preset)
001 - 256, ---
---
◎
Setup by camera
(Terminal output)
Off, On
On
◎
* Only selectable while non-Panasonic camera is connected.