66
67
■
Logs
The following logs can be checked.
Access log: Logs of accessing the recorder
•
Network log: Logs of network errors
•
To check each log, click the [View >] button.
About the access log
The date & time when logged in/out for the recorder,
the user name, and the IP address will be displayed.
Up to 100 logs are saved.
When more than 100 logs are filed, the older logs will
be overwritten by the newer logs. In this case, the
oldest log is the first to be overwritten.
**LOGIN/**LOGOUT: A user has logged in/out the
recorder.
CONFIG LOGIN/CONFIG LOGOUT: A host has
logged in/out the "HDD management" page.
UPDATE SETTINGS: Settings have been
changed.
POWER ON: The power of the recorder has been
turned on.
POWER ON(UPDATE): The recorder is rebooted
after the software is updated.
POWER ON(RESTART SWITCH): The recorder is
rebooted by pushing the Restart button.
BEFORE TIME CHANGE MANUALLY: Before the
system clock has been changed
AFTER TIME CHANGE MANUALLY: Just after the
system clock has been changed
BEFORE TIME CHANGE BY NTP: Before the sys-
tem clock has been changed by NTP
AFTER TIME CHANGE BY NTP: Just after the
system clock has been changed by NTP
** indicates a user name or an IP address.
About the network log
The network error logs (occurrence date & time and
error details) will be displayed in list form.
Up to 100 logs are saved. When more than 100 logs
are filed, the older logs will be overwritten by the
newer logs. In this case, the oldest log is the first to
be overwritten. Refer to page 91 for further informa-
tion about the error logs.
Note:
Information will not be updated while logs are
•
being displayed.
■
Functions for maintenance
License is added to operate the recorder. In addition,
settings and operations are also performed for main-
tenance of the recorder.
Note:
When using an unformatted SDHC/SD memory
•
card or an SDHC/SD memory card formatted with
a PC or another device, it is necessary to format it
with this recorder. Refer to page 138 for how to
format.
[Registration of license]
To use the recorder, it is necessary to obtain the
"Registration Key" from the key management system
and to register the license. Up to 32 cameras can be
added by registering the license of the additional
camera kit.
Contact your dealer for additional cameras. Clicking
the [Setup >] button will open the registration window
to register the license. (
☞
Page 68)
[Reset all settings]
Initializes the setting data. Click the [Execute >] but-
ton to display the confirmation window for starting
initialization.
Note:
The following setting items will not be reset to the
•
default or loaded.
HTTP port number
•
FTP port number
•
Network port
•
DNS Setup
•
License number
•
[Save data (to SD card)]
Saves the setting data on the SD memory card. Click
the [Execute >] button to display the confirmation
window to start saving.