1. Move the cursor to ALARM SETUP in the WJ-HD500
SETUP menu by pressing the
D
or
C
button, then
press the
SET
button.
The ALARM SETUP menu shown below appears on the
monitor screen.
2. Select an item or item parameter in the menu by press-
ing the
D
or
C
button.
3. To return to the previous WJ-HD500 SETUP menu,
press the
SETUP/ESC
button.
■
Alarm Port Setting
This item lets you designate the alarm input from the
ALARM port located on the rear of the Disk Recorder.
1. Move the cursor to TERMINAL TRIGGER SETUP in the
ALARM SETUP menu by pressing the
D
or
C
button,
then press the
SET
button.
The table shown below appears on the monitor screen.
2. Move the cursor to the input channel editing area by
pressing the
A
,
B
,
D
or
C
button.
3. Select a camera number (1 - 16) corresponding to the
input for the CAM editing area by pressing the
+
or
-
button.
6 ALARM SETUP
TERMINAL TRIGGER SETUP
AUTO RESET OFF
ALARM OUTPUT 2S
ALARM BUZZER 2S
VIDEO LOSS ON
VIDEO MOTION DETECTION OFF
VMD AREA SETUP
ALARM MODE MULTI OUTPUT SPOT
SPOT OUTPUT SPOT
6-1 TERMINAL TRIGGER SETUP
ALM CAM INPUT ALM CAM INPUT
1CH 1 N.O 9CH 9 N.O
2CH 2 N.O 10CH 10 N.O
3CH 3 N.O 11CH 11 N.O
4CH 4 N.O 12CH 12 N.O
5CH 5 N.O 13CH 13 N.O
6CH 6 N.O 14CH 14 N.O
7CH 7 N.O 15CH 15 N.O
8CH 8 N.O 16CH 16 N.O
4. Move the cursor to the INPUT editing area by pressing
the
B
button, then select the type of contact to meet
the system requirement by pressing the
+
or
-
but-
ton.
N.O:
Accepts alarm input from Normally Open con-
tacts.
N.C:
Accepts alarm input from Normally Closed con-
tacts.
The factory default setting is N.O.
5. Repeat the above steps 2 to 4 to designate the other
input channels.
6. When satisfied with all of the above steps, press the
SETUP/ESC
button to return to the previous ALARM
SETUP menu.
■
Alarm Auto Reset Setting
This item lets you select the duration the Disk Recorder
retains the alarm mode before resetting automatically.
1. Move the cursor to the AUTO RESET parameter in the
ALARM SETUP menu by pressing the
D
or
C
button.
2. Select the desired duration by pressing the
+
or
-
button.
OFF:
Disables auto reset.
1S - 30S, 40S, 50S, 1M - 5M:
Selects an alarm duration
between 1 second and 5 minutes.
The factory default setting is OFF.
■
Alarm Output Setting
This item lets you select the output duration of the alarm
signal from the ALARM port.
1. Move the cursor to the ALARM OUTPUT parameter in
the ALARM SETUP menu by pressing the
D
or
C
but-
ton.
2. Select the desired duration by pressing the
+
or
-
button.
OFF:
Disables alarm output, regardless of an incoming
alarm.
1S - 30S, 40S, 50S, 1M - 5M:
Selects an alarm duration
between 1 second and 5 minutes.