Panasonic Controller  

The Controller is found as a separate unit internally installed for the Monobloc unit, on the Bi-Bloc system the controller is found on the internal Hydro module.

No Displays 

Operation LED
Display of external room thermostat

Display if Solar (Hydro) active (if installed)

Indicator that back up heater is enabled ( ) or disabled
(nothing showing) 
Hot-water tank operation display (ON / OFF)

Cooling operation display (ON/OFF), (if applicable)

Heating operation display (ON / OFF)

Auto Mode OFF/ON Indicator
This icon indicates auto mode OFF/ON operation.
Display of timer setting and time

Display of outside temperature

Display of Heat Pump water flow temperature

Indicator that back up heater for heat pump and electric immersion 
heater for the hot water tank is operating (on/off) 
Display for quiet mode (ON / OFF)

Display for system programming (ON / OFF)

Display for system status (ON / OFF)

Display for in service mode (Engineers use only)

No Button assignment

Operation button (ON / OFF)

Operating mode selection button
 Use this button to select the operating mode required.
System status buttons
 These buttons are used for a series of status queries. Proceed as 
follows:
·  Press the CHECK button for 5 seconds to switch to Status mode.
·  Press the UP or DOWN button to open the following values:

  1. Compressor operating frequency
  2. Error code
  3. Water inlet temperature
  4. Water tank temperature

·  Press the CANCEL button or wait 30 seconds to quit Status 

mode.

Service button (Engineer use only)

 Button for enabling the additional electric heater for the heat 
pump. The additional electric heater can only be used if this 
button is pushed. Note: If this button is not pressed, the additional 
electric heater for the heat pump is only used for:
· Defrosting
· Device startup
· Frost protection mode
Holiday button

Quiet mode button

 System programming buttons
These buttons are used to set temperature values.
 Emergency heating mode button
This button allows the device to be operated in emergency heating 
mode with the additional electric heater for the heat pump, e.g. if 
the heat pump is defective.
 Press the ON / OFF button to switch off emergency heating mode.
 Timer programming buttons 
These buttons are used to set the time and the weekly timer.
The system is turned off by an external switch.

 Warning sign on display this is to say the following: Indicator 

that DHW is stored at +60 ºC – WARNING “HOT”

* Note: As the same operator control panel is used for different devices, some functions may not apply for your device.

3. Control panel function

OPERATION

ACTUAL

HEATER
BOOSTER
QUIET

SETTING
STATUS
SERVICE

AUTO

HEAT

COOL

TANK

HEATER

FORCE

°C

°C

ON
OFF

MON TUE WED THU FRI SAT SUN

hr

hr

kwh

1

2

3

4

5

6

7

8

9

10

11

17
18
19

16

15

14

13

12

25

26

27

28

24 23 22 21 20

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

28

27

USER GUIDE 

5

UK_MANUAL_B.indd   5

29/07/15   12:18

Summary of Contents for WH-ADC Series

Page 1: ... GUIDE FOR BI BLOC MONOBLOC ALL IN ONE WH ADC___G__ WH SDC___F__ WH SXC___F__ WH SHF___F__ WH MDC___F__ WH MHF___F__ AQUAREA USER GUIDE FOR BI BLOC MONOBLOC AND ALL IN ONE SYSTEMS UK_MANUAL_B indd 1 29 07 15 12 17 ...

Page 2: ...ners or scouring powder Service to units should be carried out by Qualified Personnel only Control Panel Do not let the control panel get wet Do not press the buttons on the control panel with hard pointed objects Otherwise it may cause damage 1 Safety precautions 2 2 Overview of ASHP system supplied 3 3 Control panel function 5 4 Operating Instructions of System 5 5 Troubleshooting 9 6 Error Faul...

Page 3: ...e also connected to house management system using KNX Modbus or Zig Bee interfaces 2 Aquarea Air High efficient radiators for heating and cooling Optional High efficient radiators working with water at 35 C No need for two kits if both floor heating and radiators are required As the product is efficient it opens the possibility to also provide cooling while still meeting construction requirements ...

Page 4: ...en the fan is turning to start the process of changing this low temperature to a high temperature using a compression cycle once the compression cycle is carried out the heat is transferred to the heating or hot water depending on requirements Monobloc Panasonic supply 2 types of heat pumps firstly a Monobloc system in this system the hot water produced to feed the heating and hot water is produce...

Page 5: ...e 3 Water inlet temperature 4 Water tank temperature Press the CANCEL button or wait 30 seconds to quit Status mode Service button Engineer use only Button for enabling the additional electric heater for the heat pump The additional electric heater can only be used if this button is pushed Note If this button is not pressed the additional electric heater for the heat pump is only used for Defrosti...

Page 6: ...N or OFF To turn ON or OFF the heat pump cooling operation To enjoy quiet environment This operation reduces heat pump unit noise In this condition it may cause decrease in heating capacity To enable the backup heater The backup heater will only operate when the setting conditions are fulfilled To disabled the Heater operation manually press the respective button again REMOTE CONTROL PREPARATION S...

Page 7: ...t operation to be carried out If HEAT or HEAT TANK is selected you are able to change the shift temperature with the UP or DOWN bottom Press the SET button to confirm Program 1 The selected day is identified with the symbol After 2 seconds the display will move to the next program 8 Repeat the steps 4 to 7 starting with the OFF ON button to set additional commands 2 to 6 if required 9 If no button...

Page 8: ...value measured by precise equipment In normal operation the and buttons are not in use Holiday mode By setting the day s in holiday mode it promotes energy saving while you are on holiday and enables the system to resume at the preset temperature after your holiday Ensure that the system is OFF before setting The system will resume operation automatically at 00 00 am after the holiday The day the ...

Page 9: ...ater in the cylinder is above 60 ºC only if controlled by A2W heat pump The operation LED blinks and error code appear on remote control display Turn the unit off and reveal the error code to authorised dealer Timer operation cancel when error code occur Force Heater Mode Button In case of a failure of the heat pump system but still power to the unit the electric heaters can be activated to provid...

Page 10: ...uoting fault code H12 Unsuitable output between the indoor and outdoor unit Contact your local Panasonic installer quoting fault code H15 Compressor temperature sensor Contact your local Panasonic installer quoting fault code H20 Water pump abnormal Reset once if reoccurring contact your local Panasonic installer quoting fault code H23 Liquid temperature sensor Contact your local Panasonic install...

Page 11: ...onic installer for more details 8 Technical Support Contact details Please call your installer as the first point of call indicating the fault or fault code otherwise please call Panasonic Technical Support 01344 853 393 for assistance Your warranty card details will be required 9 Recycling of Units After the end of the product s service life it must be disposed of appropriately The respective env...

Page 12: ...products the specifications of this catalogue are valid barring typographic errors and may be subject to minor modifications by the manufacturer without prior warning in order to improve the product The total or partial reproduction of this catalogue is prohibited without the express authorisation of Panasonic UK Ltd Contact Details Telephone 01344 853182 uk aircon eu panasonic com Address Panason...

Reviews: