25
Item
Model
VL-W1500-N
VL-W1506-N
VL-W1A00-N
VL-W1A06-N
Power voltage
90V to 132V AC or 180V to 264V AC (including ± 10% voltage fluctuations) *9
Frequency: 50/60Hz
Power
consumption
100V AC
580VA or less
740VA or less
200V AC
720VA or less
830VA or less
Grounding method
Direct earth for both the head and the controller
Cooling
method
Head
Natural air-cooling
Controller
Forced air-cooling
Operating ambient temperature *11
0°C to +40°C
Ambient temperature for storage *11
-10°C to +60°C
Operating ambient humidity *11
35 to 85%RH
Protection degree of head *12
IP54
Overvoltage category
Ⅱ
Pollution degree
2
Use location
Indoor; at an altitude of 1000 m or below
Fiber cable length
5 m ± 0.2 m, Minimum bent radius 70 mm
Installation
direction
Head
• Horizontally with the laser emission port facing downward or upward
• Vertically with the rear of the head facing upward
Controller
Vertically or horizontally
Weight
Head
Approx. 12kg
Controller
Approx. 28kg
Approx. 35kg
Battery
(mounted in
product)
Type
Graphite fluoride lithium primary battery
Model
BR-1 / 2AAC2P
Quantity
1 piece
Weight
Approx. 9.5g
*3 : Average output power from the laser welding machine at delivery time with the maximum laser power setting.
*4 : The value shown here is the configuration range that can be input. The setting values that can keep the quality of laser
processing vary depending on the setting details and the target materials.
*5 : VEC is a graphic file format dedicated for the laser welding machine.
*6 : Requires converting to VEC format with the attached “Logo Data Conversion Software”.
*7 : Check the operation before use. Use a USB flash drive formatted with FAT32. USB media with security features
cannot be used.
*8 : OS versions of which Microsoft has ended support are excluded.
*9 : The power supply voltage switches automatically.
*10 : The typical value of the inrush current at startup is as follows: (Duration time is 10ms or less.)
At 100V AC: 80A
At 200V AC: 160A
*11 : Common to the controller and the head. No condensation or freezing shall be allowed. If there is a gap between the
stored temperature and operating temperature, make sure to have the product get used to the operating ambient
temperature gradually prior to use to prevent the dew condensation.
*12 : The controller is non-compliant with the ingress protection rating. The ingress protection characteristics of the head
are ensured only when the fiber unit, cables, and the cover of the output beam diameter control are mounted properly.
ME-VLW1N-SM-1
Summary of Contents for VL-W1-N Series
Page 18: ...1 Product Overview ME VLW1N SM 1...
Page 40: ...2 Laser Welding Machine Installation ME VLW1N SM 1...
Page 64: ...3 Operation Method ME VLW1N SM 1...
Page 82: ...4 External Control Using I O ME VLW1N SM 1...
Page 122: ...5 External Control by Communication Commands ME VLW1N SM 1...
Page 126: ...6 Laser Power Monitoring Function ME VLW1N SM 1...
Page 139: ...7 Maintenance ME VLW1N SM 1...
Page 156: ...Troubleshooting ME VLW1N SM 1...
Page 171: ...Index ME VLW1N SM 1...
Page 174: ...174 MEMO ME VLW1N SM 1...
Page 175: ......