166
ERROR CODE
Description
Measures *1
E233 *2
Laser error.
• Failure of laser oscillator is detected.
• Fiber cable is broken.
• Instantaneous interruption of laser power
supply is detected.
• Temperature in the laser oscillator exceeds the
limit.
• Check and correct the power status.
• Check if the AC power line is effected by noise.
• Check the connection of the cables and
signal lines, and then restart the laser welding
machine.
• Check if the ambient temperature of the laser
welding machine is not exceeding the range of
its specification.
E234
Detected unintended-irradiation.
Contact our sales office or representatives.
E240
E241
Temperature error in laser oscillator.
• Check if the ambient temperature of the laser
welding machine is not exceeding the range of
its specification.
• Make sure air-cooling fan operates.
• Remove the dust and contamination in the air
intake and exhaust port, and clean the filter of
the air-cooling part.
• When not recovered, contact our sales office
or representatives.
E242
Temperature error in head.
• Check if the ambient temperature of the laser
welding machine is not exceeding the range of
its specification.
• Avoid placing heat sources near the head.
E250
Power supply voltage is low.
• Check and correct the power status.
• Check if the AC power line is effected by noise
from other devices.
• Check the connection of the cables and
signal lines, and then restart the laser welding
machine.
E260
Interlock is disconnected.
• Confirm the connection of the interlock
terminals.
• Check the status of the safety equipment
connected to the interlock terminals.
• Confirm operation logic of the connected
devices.
E300
Head connection error. Turn the power off and
check connection.
Turn off the power and check the followings:
• Check the head and controller model. Connect
models in the correct combination.
• Check the connection of the cables and
signal lines, and then restart the laser welding
machine.
• If the cable is disconnecting, replace it.
E310 *2
E320 *2
Unsupported combination of the head and
controller.
E311
E312
E410
Internal system error occurs in the laser welding
machine.
Check the connection of the cables and signal
lines, and then restart the laser welding machine.
E411 - E413
Internal process data in the laser welding machine
may be corrupted.
Restart the laser welding machine.
If it doesn’t reboot normally, contact our sales
office or representatives.
ME-VLW1N-SM-1
Summary of Contents for VL-W1-N Series
Page 18: ...1 Product Overview ME VLW1N SM 1...
Page 40: ...2 Laser Welding Machine Installation ME VLW1N SM 1...
Page 64: ...3 Operation Method ME VLW1N SM 1...
Page 82: ...4 External Control Using I O ME VLW1N SM 1...
Page 122: ...5 External Control by Communication Commands ME VLW1N SM 1...
Page 126: ...6 Laser Power Monitoring Function ME VLW1N SM 1...
Page 139: ...7 Maintenance ME VLW1N SM 1...
Page 156: ...Troubleshooting ME VLW1N SM 1...
Page 171: ...Index ME VLW1N SM 1...
Page 174: ...174 MEMO ME VLW1N SM 1...
Page 175: ......