ー 15 ー
ー 16 ー
■
Cross-section dimensions
■
Standard installation procedure
M5
12
12
65(60)
13
19
Tro-Reel HS Installation Manual
〈
Non-Tension Type
〉
●
Guide cap (right-angled)
Works as an end cap to
close off terminals.
●
Insulating piece
Separates circuits by providing an
insulated section on the line.
●
Hanger
Fix the Tro-Reel HS unit to
the side of the rail.
●
Collector arm
Collects power during travel.
Be sure to use in a tandem type.
Traveling speed must be 300m/min. or less (60m/min. or
less for guide-capped sections).
1P 600V, 30A (single type)
1P 600V, 60A (tandem type)
●
Center feed-in joiner
Connects the Tro-Reel HS
units together and feeds
external power to the
conductors.
●
Tro-Reel HS unit
600V, 90A with standard length of 3m
Collector arm
mount rod,12
×
12
(not included)
The values in parentheses for collector arm
(
without saddle
)
size. Attach the
collector arm to the collector arm mount plate.
The asterisk (
※
) indicates the upper conductor surface of the Tro-Reel HS unit.
※
●
In case of using a tandem type of collector arm
3P
6P
7P
8P
4P
5P
42
57
15
15
15
15
15
15
72
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
15
87
102
117
Joiner and center feed-in joiner mount holes are as shown below:
Snap the Tro-Reel HS
unit onto the hanger as
shown below.
Hanger
Tro-Reel HS
nit
Joiner mount hole dimensions (center feed-in joiner)
■
Setting intervals for hangers
Setting intervals for joiners and hangers
Joiner installation
■
Setting joiner intervals
In order to absorb expansion and
contraction due to temperature
fluctuations in the Tro-Reel HS unit,
joiners (center feed-in joiners) must
be positioned as below.
■
Setting intervals for hangers
on curved sections
Hanger installation
Mounting the Tro-Reel HS unit onto the hangers.
Nut, washer, spring washer
(not included)
●
Gap between screws
(two M5 screws; 8mm thread depth)
Insert a flat tip screwdriver
into the hanger slit. Then,
lift the upper holder
upward while pulling the
lower holder down.
■
Removing the Tro-Reel HS unit
Joiner
Rail
Joiner
Joiner
Over
R8
00m
m
Tro-Reel HS unit
1.Drill holes in the rail matching the position
of the
joiner as shown below. (See 2-2.)
2.Screw the joiner to the rail in line with the
center
mark.
500
500
500
Over R800mm
Hanger
ー
10
〜
40
℃
6000mm
1
〜
12mm
Ambient temperature
during installation
Mounting size
Distance between
conductors at joint
Failure to conform to this table may cause poor
collector arm contact or separation from wires.
The length of the Tro-Reel HS unit is 5993±2mm.
Avoid positioning
joints on curved
sections. If installation
on curved sections is
inevitable, please
mount the joint at the
straightest part of the
curved section, as
shown in the drawing.
Notes
Notes
Center mark
M5 screw
(not included)
Inward curves
(Outward curves also available.)
Hangers should be placed at
intervals of 500mm or less on
curves.
Hanger
M5 screw
(not included)
Joiner centerline
Joiner
Hanger
Rail
(300)
600
600
600
600
(300)
L
1
3
4
2-2
2-1
3P
4P
5P
7P
8P
6P
30
45
60
75
90
105
3P
150
130
15
49
5.5
×
10mm hole
4P
150
130
15
15
64
5.5
×
10mm hole
5P
150
130
15
15
79
15
5.5
×
10mm hole
6P
150
130
15
15
94
15
15
5.5
×
10mm hole
7P
150
130
15
15
109
15
15
15
5.5
×
10mm hole
8P
150
130
15
15
124
15
15
5.5
×
10mm hole
Hangers should be positioned at intervals of
600mm or less for straight sections and 500mm
or less for curved sections.In case of working
after cutting the line to L=2000mm length
or less
Should be set the hanger up to less
than 300 mm from the both
ends of joiner
L=300mmlength
or less