Status notification set up page
Sets the IP address and port number of the PC where
“Multi Monitoring & Control Software (see page 96)” is
operating when informing the PC of the status of this
unit.
Click [Detailed set up
] → [
Status notification set up].
When the status notification is set, if the unit is
malfunctioning and its power indicator is blinking orange,
the trouble content can be recognized even at a remote
location where the power indicator cannot be directly
checked.
Selection field of status notification
IP address input field for notification destination PC
Port number input field for notification destination
PC
Update button for the settings
■
SNMP set up page
Sets the various items for SNMP.
SNMP (Simple Network Management Protocol) is a
protocol to manage devices connected to the network.
If the SNMP manager is used for connection, the
information of the target device can be obtained, and its
settings can be changed.
Click [Detailed set up
] → [
SNMP set up].
[SNMP]:
Select the SNMP version to use.
[SNMP v1/v2c] [COMMUNITY]
[COMMUNITY NAME]:
Enter the community name of SNMP v1/v2c.
[PERMISSION]:
Select whether to obtain only information via SNMP
v1/v2c or to both obtain information and make the
setting.
[SNMP v3] [USER]
[USER NAME]:
Enter the user name of SNMP v3.
[PERMISSION]:
Select whether to obtain only information via SNMP
v3 or to both obtain information and make the
setting.
[
SECURITY LEVEL
]:
Select the security level for SNMP v3.
[AUTHENTICATION PROTOCOL]:
Select the authentication method for SNMP v3 from
SHA1 and MD5.
[AUTHENTICATION PASSWORD]:
Set the authentication password of SNMP v3.
[
PRIVACY PROTOCOL
]:
Select the encryption method for SNMP v3 from
AES and DES.
[
PRIVACY PASSWORD
]:
Set the encryption password of SNMP v3.
[TRAP SETTINGS]
[TRAP]:
Select the SNMP version to use when sending
TRAP.
[COMMUNITY/USER]:
Select COMMUNITY/USER to use when sending
TRAP.
When SNMP v1/v2c is selected as a SNMP version
of TRAP, the COMMUNITY 1/2 setting is used.
When SNMP v3 is selected, the USER1/2 setting
is used.
[TRAP ADDRESS]
[ADDRESS]:
Set the IP address of the SNMP manager that gives
notice of TRAP.
[PORT]:
Set the TRAP reception port number of the SNMP
manager that gives notice of TRAP.
[TRAP OPTIONS]
[POWER]:
TRAP is sent if the unit enters the standby mode by
“Power management”, [No signal power off] or [No
activity power off].
[NO SIGNAL]:
TRAP is sent if no-signal continues in the following
conditions.
When set to [ENABLE(5min)]:
TRAP is sent if no-signal continues for 5 minutes.
When set to [ENABLE(No signal error timing)]:
TRAP is sent if no-signal error set with [Setup] –
[Information timing] occurs. (see page 87)