ECO mode settings
Low power mode
When +5V DC in DVI-D IN terminal or pictures (sync signal) are not detected for about 60 seconds with DVI-D
input:
→ Power is turned off (standby); the power indicator lights up purple.
When +5V DC or pictures (sync signal) are subsequently detected:
→ Power is turned on; the power indicator lights up blue.
In the Standard mode, power consumption during sleep is higher than that in the Low power mode.
You can switch the Standard mode/Low power mode in “DVI-D power management mode” of the Options menu.
(see page 90)
Notes:
•
This function is invalid during input from DVI-D Terminal Board (TY-FB11DD).
•
Depending on the type of terminal board equipped, this function may be invalid.
•
This function may not operate depending on the video output devices.
No signal power off
Setting this to “Enable” will automatically turn the power off if there is no operation performed for approx. 10
minutes and no input synchronization signal present.
•
For WHITEBOARD input, it is judged as no signal until page loading or pen drawing is performed.
•
For MEMORY VIEWER input, it is judged as no signal when a USB memory is not connected.
•
For Panasonic APPLICATION input and MIRRORING input, it is judged as no signal in standby status.