2-4-3 Connecting to the Terminal Block of the Controller
●
In connection to the terminal block of the controller, mount a single wire or stranded wire (lead
wire) with a ferrule (sleeve) terminal (prepared separately) as shown in the figure below, and
insert it to the back of the hole.
●
When it is correctly inserted, it is locked and not removed by pulling. If it is pulled with strong
force, it may be disconnected.
●
To connect a stranded wire (lead wire) without using a ferrule (sleeve) terminal, mount it
while holding the release button.
●
To disconnect a single wire or stranded wire (lead wire), pull out the single wire or stranded
wire (lead wire) while pressing the release button.
●
0.2 to 1.5mm
2
(AWG 24 to 16) is recommend for single wire or stranded wire (lead wire).