Functions
© Panasonic Industrial Devices SUNX Co., Ltd. 2020
85
5-8 Operation monitor function
You can check the state of each connected light curtain.
The following parameters are monitored.
●
Scattered light
●
The amount of light received
●
Input / output monitor
Control output (OSSD 1 / 2)
Muting input A
Muting input B
Test / Reset input
Override input
Application indicator input 1
Application indicator input 2
Maintenance mode
When maintenance mode is set to ON, you check the state of the following settings.
● Muting beam axis A→B
● Muting beam axis B→A
● Fixed blanking beam axis
● Floating blanking beam axis
The following outputs can be forced ON or OFF.
●
Auxiliary output 1 (emitter)
●
Auxiliary output 2 (receiver)
●
Muting auxiliary output (emitter)