4-17 Interlock / external device monitor function
When you click "Interlock / external device monitor" in the function settings / configuration set
-
tings screen, the following screen appears.
3
5
7
6
1
2
4
1.
To configure interlock settings from the light curtain cable, select this checkbox. To configure
the settings from the software, remove the checkmark.
2.
If you remove the checkmark in
1
, the selection screen for the reset method and interlock
mode activates. Select manual reset or automatic reset. If you select manual reset, interlock
mode is also selected.
3.
To monitor an external device (forcible guide relay, magnetic conductor, etc.) from the light
curtain, select the checkbox.
4.
To use the external device monitor, set the external device delay time.
5.
Initialize the settings.
6.
Finalize the settings and return to the function settings / configuration settings screen.
7.
Cancel the settings and return to the function settings / configuration settings screen.
For function details, refer to
and
setting (8-core cable, 12-core cable)"
.