Slide 93
Troubleshooting Horizontal Line Problem
SS,SS2
SS,SS2
SU
SU
PDP panel
SC
SC
Scan Drive:
Pulse timing is shifted each horizontal electrode.
・
・
・
・
・
・
・
・
・
SCAN
DRIVE
IC
1 line abnormal
SD
SD
Sustain Drive:
All the lines are same waveform.
All the lines are connected mutually.
SS board doesn't cause
horizontal lines problems. All
the electrodes on SS board are
common.
A horizontal line can be caused by: A defective scan
drive IC , open connection to the panel or damaged
electrode within the panel.
When this cable (FFC) is damaged,
replace the panel. The FFC is bonded
to the panel directly.