5. SPECIFICATIONS
Designation
PCI bus
S-LINK V
control board
Item
Model No.
SL-VPCI
Supply voltage
(Note 1)
[
S-LINK V
system side] +24V DC
+10
-5
%
[PCI bus side] +5V DC ±5%
Current consumption
[+24V DC] 85mA or less (Note 2)
[+24V DC (power supply for
S-LINK V
I/O units and load)] Max. supply current: 7A (Note 3)
[+5V DC] 315mA or less
Transmission speed
A mode: 110kbps, B mode: 27.5kbps, C mode: 6.9kbps
Connection method
“T” branch connection or multi-drop connection
Transmission distance
A mode: 50m max., B mode: 200m max., C mode: 800m max.
Total wiring length
A mode: 100m or less, B mode: 400m or less, C mode: 1,600m or less
Suitable
transmission cable
Exclusive 4-core flat cable (0.5mm
2
) or Conductor cross-section area 0.3 to 2.0mm
2
4-core VCTF cable (without shield)
I/O points
Max. 512 points (For one port) (I/Os settable in units of 32 points with dip switch and in units of 16 points with a program)
Connectable nodes
Max. 256 nodes
Compatible bus
(Note 4)
PCI bus
Assignment
Plug and play
Ambient temperature
(Note 5)
0 to +55ºC (No dew condensation allowed), Storage: -20 to +70ºC
Ambient humidity
(Note 5)
20 to 85% RH, Storage: 20 to 85% RH
Noise immunity
(Note 5)
Power line: 500Vp, 10ms cycle, and 1µs pulse width
Common: 1,000Vp, 10ms cycle, 1µs pulse width (with noise simulator)
Voltage withstand-
ability (Note 5)
1,000V AC for one min. between external terminals and ground
Insulation resistance
(Note 5)
20MΩ, or more, with 500V DC megger between external terminals and ground
Vibration resistance
(Note 5)
10 to 150Hz frequency, 0.75mm amplitude in X, Y and Z directions for two hours each
Shock resistance
(Note 5)
98m/s
2
acceleration (approx. 10G) in X, Y and Z directions for three times each
Grounding method
Bracket: Floating,
S-LINK V
system side: Capacitor coupling
Interruption function
(Note 6)
Interruption will be performed if an error or input change occurs (enabling / disabling this function is possible.)
Notes: 1) +24V DC and +5V DC are isolated.
2) The current consumption value is the total of the maximum current value (D - G line only) supplied to the
S-LINK V
I/O units and the current consumption value of the
S-LINK V
control board.
3) This product is not equipped with any short-circuit protective function. For this reason, select a power
supply unit having a short-circuit protective function (fuse, etc.).
4) If you need a driver, download the driver from our website (https://panasonic.net/id/pidsx/global). [We can
provide drivers for DOS, Windows 95/98/Me (32bit), Windows NT 4.0 (32bit), Windows 2000/XP/7 (32bit)
and Windows 10 (64bit).] If you cannot access to our website, please contact the store where you bought
our product or our sales office.
5) The value is for the control board single body. If the control board is installed on the computer, the
specifications of control board with those of the computer, and observe the specifications showing the lower
value.
6) The interruption function can be enabled or disabled for each point. However, the interruption condition
(ON → OFF / OFF → ON) is applied to all input points, and application to each point is not possible.
6. INTENDED PRODUCTS FOR CE MARKING
●
The models listed under “
5. Specifications