Page 23/28
RX550DC MOTOR OPTIONS
These settings allow the receiver to be tailored to
different pan/tilt motors. The MIN/MAX values
MAX PAN 255
set the minimum and maximum speeds during manual control
MIN PAN 15
255 is maximum speed and 0 is minimum
MAX TILT 255
If the minimum is too low, the head may stall at low
MIN TILT 50
speeds.
To increase pan/tilt head life, the pan and tilt
MAX PRE PAN 255
speeds can be reduced during preset calls. Again take
MAX PRE TILT 255
care that the head doesn't stall.
RETURN
RETURN to TEST MENU
MOTOR OPTIONS