Chapter 5
Operations — Web control function
ENGLISH - 117
r
[WARNING] items
Item
Description
[INTAKE AIR TEMPERATURE]
The intake air temperature is high. The projector may be used in an environment where
the temperature is high, such as near a heating appliance.
[OPTICS MODULE TEMPERATURE]
The temperature around the optics module inside the projector is high. The projector
may be used in an environment where the temperature is high, such as near a heating
appliance.
[LD MODULE TEMPERATURE]
The temperature of the light source is high. The projector is possibly used in an
environment where the temperature is high, such as near a heating appliance.
[LOW-TEMPERATURE]
The internal temperature of the projector or ambient temperature is low. Projection
cannot be started until the internal temperature of the projector or ambient temperature
becomes warm.
[BATTERY]
Replacement of built-in battery is required. Consult your dealer.
[Network status] page
Click [Status]
→
[Network status].
The current network setting status is displayed.
2
1
1 [WIRELESS LAN]
Displays the settings of wireless LAN.
2 [WIRED LAN]
Displays the settings of wired LAN.
[Access error log] page
Click [Status]
→
[Access error log].
The error log on the web server is displayed such as access to the pages that do not exist or access with
unauthorized user names or passwords.
[E-mail error log] page
Click [Status]
→
[E-mail error log].