46
PAW-VP•LDHW - Technical Manual – 2020-07
Performance Characteristic Tables
3
3.6 Heating capacity table PAW-VP380L
Operation type:
Heating capacity
Outdoor unit type:
U-200PZH2E8
Tank type:
PAW-VP380L
Ambient
temperature
Δt 10K
Heating capacity
Power Input
COP
Water Outlet
[kW]
[kW]
[kW/kW]
+25°C
35°C
25.95
5.18
5.01
40°C
24.95
5.38
4.64
45°C
24.45
5.83
4.19
50°C
21.82
6.39
3.41
+20°C
35°C
25.50
5.52
4.62
40°C
24.70
5.72
4.32
45°C
24.20
5.72
4.23
50°C
21.58
6.73
3.21
+15°C
35°C
23.25
7.18
3.24
40°C
22.45
7.38
3.04
45°C
21.95
7.83
2.80
50°C
19.33
8.39
2.30
+10°C
35°C
25.20
7.07
3.56
40°C
24.40
7.27
3.36
45°C
23.90
7.72
3.10
50°C
21.28
8.28
2.57
+7°C
35°C
25.00
7.03
3.56
40°C
24.20
7.23
3.35
45°C
23.70
7.23
3.28
50°C
21.08
8.24
2.56
+2°C
35°C
23.00
6.94
3.31
40°C
22.20
7.14
3.11
45°C
21.70
7.59
2.86
50°C
19.08
8.15
2.34
+0°C
35°C
22.50
6.88
3.27
40°C
21.70
7.08
3.06
45°C
21.20
7.53
2.82
50°C
18.58
8.08
2.30
-7°C
35°C
20.06
5.52
3.63
40°C
19.80
5.72
3.46
45°C
19.30
6.16
3.13
50°C
16.68
6.73
2.48
-10°C
35°C
19.30
5.18
3.73
40°C
18.50
5.38
3.44
45°C
18.00
5.83
3.09
50°C
15.38
6.39
2.41
-15°C
35°C
17.00
4.60
3.70
40°C
16.20
4.82
3.36
45°C
15.70
5.27
2.98
50°C
13.08
5.83
2.24
-20°C
35°C
14.50
4.01
3.62
40°C
13.70
4.21
3.25
45°C
13.20
4.66
2.83
50°C
10.58
5.23
2.02
Please note: The data mentioned in this document is obtained by calculation.
Please use only for reference.