4.3.4.
Information Code: 416
START
END
Is communication with the
reference unit successful?
Change Function Parameter
#011: Reduce Rx Sensitivity
Level
Yes
No
Yes
No
Change Function Parameter
#023: Increase Training
Check Period
Does the problem still occur?
1. Replace the SC PCB.
Refer to Sect. 4.6.
Does the problem still occur?
Change Function Parameter
#013: Increase G3 Rx
Equalization
Does the problem still occur?
END
Does the problem still occur?
Yes
No
No
Yes
No
Yes
Check the telephone line
condition.