071 TOTAL ERROR 1 = 5%
2 = 10%
3 = 15%
4 = 20%
Selects the transmit condition of RTP/PIP or RTN/
PIN.
(Available if No.73 Error Detect is set to "RATE".)
(See Note 2)
072 CONTINUOUS
ERROR
1 = Off (unlimited)
2 = 3 lines/STD
3 = 6 lines/STD
4 = 12 lines/STD
Selects the continuous total error criteria of Off/3/6 or
12 lines in Standard mode. If continuous total error
exceeds this setting, the unit will transmit RTN/PIN.
(Available if No.73 Error Detect is set to "RATE".)
073 ERROR
DETECT
1 = Lines
2 = Rate
Selects the error detect condition Lines/Rate.
074 RTN RECEIVE
1 = Disconnect
2 = Continue
Selects whether to disconnect the phone line or
continue when "RTN" is received.
075 CODING
1 = MH (MH only)
2 = MR (MH or MR)
3 = MMR
(MH or MR or MMR)
Selects the coding scheme.
076 Not Used
077 RX JAM
LENGTH
1 = Off (unlimited)
2 = 2 m
3 = 8 m
Selects the maximum length of a received document
that can be printed.
078
079
Not Used
080 DOC. TOP
FEED
-5.0 mm
~
+5.0 mm
Adjusts the distance between the scanning sensor
ON position and the scanning start position.
081 DOC. END
FEED
-5.0 mm
~
+5.0 mm
Adjusts the distance between the scanning sensor
OFF position and the scanning end position.
082 JAM LENGTH
1 = 1 m
2 = 2 m
3 = 8 m
4 = Unlimited
Selects the maximum length of the original that can
be scanned.
083 Not Used
084 LINE AS NO
PAPER
1 = Ring (ring)
2 = Busy (keep line busy)
Selects whether to ring or send a busy tone to the
remote station when the recording paper runs out or
the unit cannot receive because of any trouble.
085 Not Used
086 REDUCTION
FINE
1 = Off
2 = On
Selects whether the resolution is preset to Fine,
when sending with reduction B4
→
A4.
(For B4 Scanning Model only)
087 DARKER LEVEL 0 = Lightest Contrast
~
15 = Darkest Contrast
Selects the contrast level.
0
←
→
15
Lightest
←
→
Darkest
088 NORMAL LEVEL
089 LIGHTER LEVEL
090 PRINT DENSITY 1 = Normal
2 = Darker
Print Density sometimes gets light at low Humidity
condition. In this case, selects “2:Darker”.
(Except for U.S.A. and Canada)
091 Not Used
092 SMOOTHING
1 = Off
2 = On
Selects whether the smoothing function is available.
Function Parameter Table
No.
Parameter
Selections
Function
Summary of Contents for Panafax UF-4000
Page 4: ...4 ...
Page 8: ...8 memo ...
Page 21: ...21 1 4 Control Panel For USA and Canada UF 490 UF 4000 ...
Page 22: ...22 For Other Destinations UF 490 UF 4100 UF 4100 ABBR ...
Page 44: ...44 24 Remove the Pressure Roller 322 25 Remove the Exit Roller 304 24 25 ...
Page 70: ...70 3 10 ILS PC Board CN73 Refer to SC PC Board CN11 ...
Page 72: ...72 3 12 ACI PC Board Refer to Power Supply Unit CN101 ...
Page 232: ...232 801 803 802 Fig 8 Cartridge Unit K A C D E F G H I J B 8 1 3 4 5 6 7 2 2 2 ...