140
Note:
If an 021 series Error Code occurs, 021-25 (Thermistor Open) or 021-26 (Thermistor detected
temperature over 365
°
F (185
°
C), a pre-programmed recovery safety software is activated to protect the
unit and the service personnel during abnormal increase in temperature.
Once activated, disabling the Fuser Lamp and preventing it from turning ON again.
In order to reset this circuit, please follow the procedure below.
1) Reset the LBP Fuser by using Service Mode 7-1-2 (Section 5.1.7.) and Power OFF/ON.
2) Replace the Thermistor or Fuser Unit. If the problem persists.
3) Replace the SC PCB.
82 Illegal response from the LP Controller
1. SC PCB defective.
Error
Code
Description of Problems
Cause