12
Power Supply
1 Power Requirement
108 - 132 VAC, 47 - 63 Hz, Single Phase 100 VAC Power Supply
198 - 255 VAC, 47 - 63 Hz, Single Phase 200 VAC Power Supply
2 Power Consumption
Standby
Sleep Mode Less than 0.7 Wh
ES=On
5.5 Wh ± 25%
ES=Off
17 Wh ± 25%
Transmission
17 W ± 25%
Reception
450 W ± 15%
Copy
450 W ± 15%
Maximum
470 W
100 VAC Power Supply
ES: Energy Saver
Standby
Sleep Mode Less than 1.0 Wh
ES=On
6.0 Wh ± 25%
ES=Off
17 Wh ± 25%
Transmission
17 W ± 25%
Reception
460 W ± 15%
Copy
460 W ± 15%
Maximum
470 W
200 VAC Power Supply
ES: Energy Saver
Environment
1 Temperature
Operation
50 to 95
°
F ( 10 to 35
°
C)
Storage
-4 to 104
°
F (-20 to 40
°
C)
Transport (Max. 72 hours)
-4 to 122
°
F (-20 to 50
°
C)
2 Relative Humidity
Operation
15 to 70% RH
Storage
5 to 85% RH
Transport (Max. 480 hours)
15 to 85% RH
Standards
1 Safety
UL60950-1:2003
CSA C22.2 No.950
HHS Part
1040:1993
UL1950
CSA C22.2 No.950
2 PSTN
FCC Part 68: 2002
CS-03:Issue 8 1996
FCC Part 68
DOC No. CS-03
3 EMI
ClassB computing device
in FCC Part 15
Construction
1 Dimensions (W x D x H)
14.0 x 14.3 x 8.7 in
(355 x 364 x 220 mm)
Excluding projections
2 Weight (Excluding paper)
16.1 lb
(7.3 kg)
Excluding consumable
supplies and options
Items
Description
Remarks
UF-4000/4100
UF-490
Summary of Contents for Panafax UF-4000
Page 4: ...4 ...
Page 8: ...8 memo ...
Page 21: ...21 1 4 Control Panel For USA and Canada UF 490 UF 4000 ...
Page 22: ...22 For Other Destinations UF 490 UF 4100 UF 4100 ABBR ...
Page 44: ...44 24 Remove the Pressure Roller 322 25 Remove the Exit Roller 304 24 25 ...
Page 70: ...70 3 10 ILS PC Board CN73 Refer to SC PC Board CN11 ...
Page 72: ...72 3 12 ACI PC Board Refer to Power Supply Unit CN101 ...
Page 232: ...232 801 803 802 Fig 8 Cartridge Unit K A C D E F G H I J B 8 1 3 4 5 6 7 2 2 2 ...
Page 250: ...250 memo ...
Page 283: ...memo ...
Page 284: ...DZZSM00309 ...