-14-
Installation
The amplifier and motor should be properly installed to avoid failures, mechanical damages and injuries.
Amplifier
Location
•
Indoors, where the amplifier is not subjected to rain water and direct sun beams. Note
that the amplifier is not a waterproof structure.
•
Avoid the place where the amplifier is subjected to corrosive gases, flammable gases,
grinding liquids, oil mists, iron powders and cutting particles.
•
Place in a well-ventilated, and humid- and dust-free space.
•
Place in a vibration-free space.
Environmental Conditions
How to Install
•This is a rack-mount type.
Place the amplifier vertically. Allow enough space surrounding for ventilation.
Front panel mount type (recessed)
I t e m
Ambient temperature
Ambient humidity
Storage temperature
Storage humidity
Vibration
Altitude
C o n d i t i o n s
0 to 55˚C (free from freezing)
Not greater than 90%RH (free from condensation)
-20 to 80˚C (free from condensation)
Not greater than 90%RH (free from condensation)
Not greater than 5.9m/s
2
(0.6G) at 10 to 60 Hz
Not greater than 1000 m
Earth connection (M4 screw) tightening torque
shall not exceed 0.39 ~ 0.59 N·mU.U
MSDS
MOTOR
CN
SIG
CN
CN
POWER
CN
I/F
ALM CODE
STATUS
GAIN
CN
SER