8-5. Backup Function
This function is used for not storing the threshold value obtained from external input teaching into the EEPROM.
It prevents unnecessary writing to the EEPROM.
* Equipped with cable type only.
Backup
OFF
Backup
ON
Press the
MODE key 5 times.
Turn the Jog switch 4 times
toward the ‘
’ direction.
Turn the Jog switch 3 times
toward the ‘
’ direction.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Press the
MODE key once.
Press the
MODE key once.
The digital display will quickly
blink to confirm the setting.
Select from backup ON / backup OFF
by turning the Jog switch.
1
Press the [MODE key] 5 times to select ‘PRO mode’.
3
Press the [Jog switch] to enter the ‘copy setting’ state.
2
Turn the [Jog switch] 4 times toward the ‘
’ direction, to
select ‘PRO4 mode’.
4
Turn the [Jog switch] 3 times toward the ‘
’ direction, to
enter the ‘backup setting’ state.
8
If the [MODE key] is pressed once, the amplifier will return to
‘PRO4 mode’.
9
Press the [MODE key] once, the amplifier will return to ‘RUN
mode’ (normal sensing operation).
5
If the [Jog switch] is pressed, the current setting (red) will be
displayed.
* The factory setting is ‘Backup OFF’.
6
If the [Jog switch] is turned, the setting (red) will blink on the
digital display.
Select from either ‘Backup ON’ or ‘Backup OFF’.
7
If the [Jog switch] is pressed, the setting (red) will quickly
blink on the digital display, confirming ‘Backup ON / OFF’.
The digital display will not blink (red) if the setting has not
been changed.
45
Ramco National
(800) 280-6933
www.panasonicsensors.com