8-2. Copy Function
By utilizing the optical communications function, the settings information from the operating amplifier can be
copied to other connected amplifiers. (Except for data bank contents) However, the 0-Adjust function and
transmission change to permit / not to permit function will not be copied. However, in amplifiers in which the
transmission change has not been permitted, copying will not occur.
Please refer to p. 38
Optical communications
for the direction of optical communication.
Press the
MODE key 5 times.
Turn the Jog switch 4 times
toward the ‘
’ direction.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Press the
MODE key once.
Press the
MODE key once.
The digital display will blink
3 times to confirm the setting.
The digital display
will scroll (twice).
Also displayed
on amplifiers
on which copy
is done.
1
Press the [MODE key] 5 times to select ‘PRO mode’.
3
Press the [Jog switch] to enter the ‘copy setting’ state.
6
If the [MODE key] is pressed once, the amplifier will return to
‘PRO4 mode’.
7
Press the [MODE key] once, the amplifier will return to ‘RUN
mode’ (normal sensing operation).
5
If the [Jog switch] is pressed while ‘ ’ (red) is blinking, the
digital display will scroll (twice) and the settings information will
be copied. Then ‘ ’ (red) will blink 3 times, confirming the
setting.
However, for amplifiers in which the transmission change
has not been permitted, ‘ ’ (red) will blink 3 times.
* When communication error has occurred, ‘ ’ (red) will be
displayed. Confirm that all amplifiers are properly connected to
each other.
4
If the [Jog switch] is pressed, the letters ‘ ’ (red) will blink.
2
Turn the [Jog switch] 4 times toward the ‘
’ direction, to
select ‘PRO4 mode’.
42
Ramco National
(800) 280-6933
www.panasonicsensors.com