6-6. Current Value Storage Function
The current incident light intensity value can be stored.
Press the
MODE key 5 times.
Press the
Jog switch.
Press the
Jog switch.
Press the
Jog switch.
Turn the Jog switch twice
toward the ‘
Ⳮ
’ direction.
Turn the Jog switch 4 times
toward the ‘
Ⳮ
’ direction.
Press the
MODE key once.
The digital display will quickly
blink to confirm the setting.
Press the
MODE key once.
5
If the [Jog switch] is pressed, the current ‘incident light
intensity’ (red) will be displayed.
7
If the [MODE key] is pressed once, the amplifier will return to
‘PRO2 mode’.
8
Press the [MODE key] once, the amplifier will return to ‘RUN
mode’ (normal sensing operation).
6
If the [Jog switch] is pressed, incident light intensity (red) will
quickly blink on the digital display, and the data will be
stored.
4
Turn the [Jog switch] 4 times toward the ‘
Ⳮ
’ direction, to
enter the ‘current value storage setting’ state.
3
Press the [Jog switch] to enter the ‘display switching’ state.
2
Turn the [Jog switch] twice toward the ‘
Ⳮ
’ direction, to
select ‘PRO2 mode’.
1
Press the [MODE key] 5 times to select ‘PRO mode’.
36
Ramco National
(800) 280-6933
www.panasonicsensors.com