1.4 Specifications
32
Installation Manual
1.4
Specifications
1.4.1
General Description
Control Bus
Original bus (16-bit, 8 MHz, 10 megabytes per second)
Communication Bus
H.100 bus conformity (1024 time slots)
Switching
Distributed Switching
Power Input
PSU-M
100 V AC to 130 V AC; 2.5 A/200 V AC to 240 V AC; 1.4 A;
50 Hz/60 Hz
PSU-L
100 V AC to 130 V AC; 5.1 A/200 V AC to 240 V AC; 2.55 A;
50 Hz/60 Hz
Maximum Power Failure Tolerance
*1
300 ms
Power Consumption
(per shelf)
With PSU-M
190 W; 2.5 A (at 120 V AC; 60 Hz)
With PSU-L
410 W; 5.1 A (at 120 V AC; 60 Hz)
Memory Backup Duration
7 years
Dialing
CO Line
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Extension
Dial Pulse (DP) 10 pps, 20 pps
Tone (DTMF) Dialing
Mode Conversion
DP-DTMF, DTMF-DP
Ring Frequency
20 Hz/25 Hz (selectable)
Central Office Loop Limit
1600
Ω
maximum
Operating
Environment
Temperature
0 °C to 40 °C (32 °F to 104 °F)
Humidity
10 % to 90 % (non-condensing)
Conference Call CO Line (per shelf)
From 10 × 3-party conference call to 4 × 8-party conference
call
Music on Hold (MOH)
2 ports (Level Control: -11 dB to +11 dB in 1 dB steps)
MOH1: External Music Source port
MOH2: Selectable Internal/External Music Source port
Paging
Internal
Level Control: -15 dB to +6 dB in 3 dB steps
External
2 ports (Volume Control: -15 dB to +15 dB in 1 dB steps)
Serial Interface Port
RS-232C
1 (maximum 115.2 kbps)
USB
1
Summary of Contents for KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008...
Page 7: ...Installation Manual 7 SAVE THESE INSTRUCTIONS ...
Page 40: ...1 4 Specifications 40 Installation Manual ...
Page 208: ...2 14 Starting the Hybrid IP PBX 208 Installation Manual ...
Page 216: ...3 3 Installation of the KX TDA600 Maintenance Console 216 Installation Manual ...
Page 227: ...Installation Manual 227 Index ...
Page 231: ...Index Installation Manual 231 ...