2.9 Connection of Extensions
166
Installation Manual
With DPT
Parallel mode or eXtra Device Port (XDP) mode can be selected through system programming.
If XDP mode is enabled through system programming, parallel connection is not possible. Refer to "1.13.2
Paralleled Telephone" and "1.5.7 Extension Port Configuration" in the Feature Manual for further
information.
Using a Modular T-Adaptor
Using an EXtra Device Port
With KX-T7600 Series DPT
To DHLC8 card
SLT
DPT
Modular
T-Adaptor
4-conductor wiring cord
Connect pins "D1" and
"D2".
2-conductor wiring cord
Connect pins "T" and "R".
To DHLC8 card
DPT
SLT
To DHLC8 card
To SLT
2-conductor wiring cord
Connect pins "T" and "R".
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
TO MAIN UNIT
/ PABX
TO TEL