![Panasonic KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008... Installation Manual Download Page 147](http://html1.mh-extra.com/html/panasonic/kx-tda600-hybrid-ip-pbx-control-unit-max-1008/kx-tda600-hybrid-ip-pbx-control-unit-max-1008_installation-manual_4002180147.webp)
2.7 Information about the Extension Cards
Installation Manual
147
Pin Assignments
Amphenol Connector
LED Indications
No.
Signal Name Function
No.
Signal Name Function
1
RA
Ring port 1
26
TA
Tip port 1
2-3
Reserved
–
27-28
Reserved
–
4
RB
Ring port 2
29
TB
Tip port 2
5-6
Reserved
–
30-31
Reserved
–
7
RC
Ring port 3
32
TC
Tip port 3
8-9
Reserved
–
33-34
Reserved
–
10
RD
Ring port 4
35
TD
Tip port 4
11-12
Reserved
–
36-37
Reserved
–
13
RE
Ring port 5
38
TE
Tip port 5
14-15
Reserved
–
39-40
Reserved
–
16
RF
Ring port 6
41
TF
Tip port 6
17-18
Reserved
–
43-44
Reserved
–
19
RG
Ring port 7
44
TG
Tip port 7
20-21
Reserved
–
45-46
Reserved
–
22
RH
Ring port 8
47
TH
Tip port 8
23-25
Reserved
–
48-50
Reserved
–
Indication
Color
Description
CARD STATUS
Green/Red
Card status indication
•
OFF: Power Off
•
Green ON: Normal (all ports are idle)
•
Green Flashing (60 times per minute): Normal (a port is in use)
•
Red ON: Fault (includes reset)
•
Red Flashing (60 times per minute): Out of Service
50 25
26 1
Summary of Contents for KX-TDA600 - Hybrid IP PBX Control Unit Max. 1008...
Page 7: ...Installation Manual 7 SAVE THESE INSTRUCTIONS ...
Page 40: ...1 4 Specifications 40 Installation Manual ...
Page 208: ...2 14 Starting the Hybrid IP PBX 208 Installation Manual ...
Page 216: ...3 3 Installation of the KX TDA600 Maintenance Console 216 Installation Manual ...
Page 227: ...Installation Manual 227 Index ...
Page 231: ...Index Installation Manual 231 ...