2.11 Connection of Doorphones, Door Openers, External Sensors, and External Relays
196
Installation Manual
2.11 Connection of Doorphones, Door Openers,
External Sensors, and External Relays
2.11.1 Connection of Doorphones, Door Openers, External
Sensors, and External Relays
The Hybrid IP-PBX supports a maximum of 64 doorphones, 64 door openers, 64 external sensors, and 64
external relays.
Note
Doorphones, door openers, external sensors, and external relays are user-supplied.
Maximum Cabling Distance
Installing the Doorphone (KX-T30865)
1.
Loosen the screw to separate the doorphone into 2 halves.
Doorphone
Door Opener
External Sensor/
External Relay Device
Cable
Maximum Distance
26 AWG:
70 m (230 ft)
24 AWG:
113 m (371 ft)
22 AWG:
180 m (590 ft)
CAT 5:
113 m (371 ft)