2.9 [2] System
338
PC Programming Manual
Programming Manual References
None
Feature Manual References
1.3.1 Caller ID
Send Caller ID Long Distance to Extension
Enables the PBX to send a call qualifier (Long Distance) (if received from the CO line) when sending
Caller ID information to an SLT.
Default
Enable
Value Range
Disable, Enable
Maintenance Console Location
2.9.18 [2-10] Extension CID Settings
Programming Manual References
None
Feature Manual References
1.3.1 Caller ID
FSK Transmission Level
Specifies the transmission level for FSK signal modulation.
Default
0 dB
Value Range
-14 dB, -12 dB, -10 dB, -8 dB, -6 dB, -4 dB, -2 dB, 0 dB
Maintenance Console Location
2.9.18 [2-10] Extension CID Settings
Programming Manual References
None
Feature Manual References
1.3.1 Caller ID