2.8 [1] Configuration
206
PC Programming Manual
Programming Manual References
2.8.25 [1-1] Slot—OPB3 Card Property (KX-TDA100/KX-TDA200/KX-TDA600 only)
Feature Manual References
None
2.8.28 [1-1] Slot—Card Property - CTILINK (KX-TDA100/KX-
TDA200/KX-TDA600 only)
The properties of the CTI-LINK card can be specified.
Note that the IP address information must be specified in accordance with the settings of the network
that it will be used on.
IP Address
Specifies the IP address of the PBX.
Default
192.168.0.1
Value Range
1.0.0.0–223.255.255.255
Maintenance Console Location
2.8.28 [1-1] Slot—Card Property - CTILINK (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Manual References
1.3.21 CTI (Computer Telephony Integration)
Subnet Mask
Specifies the subnet mask of the PBX.
Default
255.255.255.0
Value Range
0–255.0–255.0–255.0–255 (except 0.0.0.0 and 255.255.255.255)
Maintenance Console Location
2.8.28 [1-1] Slot—Card Property - CTILINK (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References