2.6 Connection of Extensions
Installation Manual
91
With KX-T7600E Series DPT
Using a Modular T-Adaptor
4-conductor wiring cord
Connect pins "D1" and "D2".
Slave DPT
SLT
Master DPT
Modular
T-Adaptor
4-conductor wiring cord
Connect pins "D1" and "D2".
2-conductor wiring cord
Connect pins "T" and "R".
Slave DPT
Master DPT
TO MAIN UNIT
/ PABX
TO DIGITAL
TO MAIN UNIT
/ PABX
Cable
Maximum Distance
ø 0.4 mm:
30 m
ø 0.5 mm:
50 m
ø 0.6 mm:
60 m
CAT 5:
50 m
Back View of DPTs