1.4 Specifications
Installation Manual
27
Load Figure Calculation (BRI Extension Port)
If the Hybrid IP-PBX has a BRI extension port, you need to calculate the total load figure from the type and
number of equipment to be connected.
If the total load figure exceeds 32, it cannot be supported by the KX-TDA15. In this case, use the KX-TDA30
with Additional AC Adaptor. If the load figure exceeds 96, use the KX-TDA100 with M-Type Power Supply
Unit (PSU-M), or the KX-TDA200 with either PSU-M or L-Type Power Supply Unit (PSU-L).
Calculation Example
Equipment Type
Load Figure
PT
KX-T7600 series DPT/KX-T7600 series DSS
console
0
KX-T7560/KX-T7565 DPT
0
Other DPT/Other DSS console
4
APT
4
IP-PT
0
Pre-installed 4 Super Hybrid Ports
0
Extension Card
SLC8
0
CS (1 unit)
4
VPS (1 port)
0
ISDN Telephone
1
*1
*1
If the connected ISDN telephone has an external power source, its load figure is 0.
Equipment Type
Load Figure
Other DPT/Other DSS console (except KX-
T7600 series, KX-T7560/KX-T7565)
4 units
16
CS
2 units
8
ISDN Telephone
1 unit
1
Total
25
Summary of Contents for KX-TDA15
Page 5: ...Installation Manual 5 SAVE THESE INSTRUCTIONS ...
Page 14: ...14 Installation Manual ...
Page 28: ...1 4 Specifications 28 Installation Manual ...
Page 155: ...Installation Manual 155 Section 5 Appendix ...
Page 159: ...Installation Manual 159 Index ...
Page 162: ...Index 162 Installation Manual ...