2.6 Connection of Extensions
90
Installation Manual
Using an EXtra Device Port
SLT
Master DPT
Slave DPT
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
2-conductor wiring cord
Connect pins "T" and "R".
4-conductor wiring cord
Connect pins "T", "R",
"D1" and "D2".
Slave DPT
Master DPT
To SLT
TO MAIN UNIT
/ PABX
TO TEL
TO TEL
TO MAIN UNIT
/ PABX
Cable
Maximum Distance
ø 0.4 mm:
30 m
ø 0.5 mm:
50 m
ø 0.6 mm:
60 m
CAT 5:
50 m
Back View of DPTs
To a Super Hybrid Port
To a Super Hybrid Port
Summary of Contents for KX-TDA15
Page 5: ...Installation Manual 5 SAVE THESE INSTRUCTIONS ...
Page 14: ...14 Installation Manual ...
Page 28: ...1 4 Specifications 28 Installation Manual ...
Page 155: ...Installation Manual 155 Section 5 Appendix ...
Page 159: ...Installation Manual 159 Index ...
Page 162: ...Index 162 Installation Manual ...