LED Indications
Indication
Color
Description
RUN
Green
OFF: Power Off (includes normal reset)
ON: Power On and running (on-line)
Flash (60 times per minute): Power On and starting
Flash (120 times per minute): Power On and resetting before system clear
ALARM
Red
OFF: Normal
ON: Alarm (CPU stop, alarm for each card)
Flash: Alarm (MPR file error in restarting)
Confirming the CO Line Connection
After initialization, program the Hybrid IP-PBX and establish CO line connection, and then use a
PT to confirm it.
To confirm, dial [
] [3] [7] + CO line number (3 digits) or press S-CO button (CO01 to CO64).
You will hear a dial tone if CO line is available and connected.
Using the Reset Button
If the Hybrid IP-PBX does not operate properly, use the Reset Button. Before using the Reset
Button, try the system feature again to confirm whether there definitely is a problem or not.
Note:
1. When the System Clear Switch is set to "NORMAL", pressing the
Reset Button causes the following:
- Camp-on is cleared.
- Calls on hold are terminated.
- Calls on exclusive hold are terminated.
- Calls in progress are terminated.
- Call park is cleared.
Other data stored in memory, except the above, are not cleared.
2. When the System Clear Switch is set to the "SYSTEM INITIALIZE"
position, you must press the Reset Button with caution, because
all data stored in memory will be cleared by the following
operation: (1) pressing the Reset Button and then, (2) setting the
System Clear Switch to the "NORMAL" position while the RUN
indicator is flashing (within approximately 10 s).
10
Summary of Contents for KX-TDA0187
Page 5: ...4 NAMES AND LOCATIONS Overview Inside View 5 ...
Page 13: ...5 TROUBLESHOOTING GUIDE 13 ...
Page 14: ...14 ...
Page 15: ...15 ...
Page 16: ...16 ...
Page 27: ...27 ...
Page 29: ...8 IC DATA 8 1 IC1 CPU 29 ...
Page 31: ...31 ...
Page 35: ...DIODES 11 CABINET AND ELECTRICAL PARTS LOCATION 35 ...
Page 36: ...12 ACCESSORIES AND PACKING MATERIALS 36 ...
Page 37: ...37 ...