2.7 Connection of DECT Portable Stations
92
Installation Manual
b.
If 1 CS cannot cover the entire service area, install additional CSs as required.
Overlap the coverage areas of adjacent CSs.
Where CS coverage areas overlap, the PS will start call handover to the next CS if the
signal from one CS becomes weak. However, if a PS moves away from a CS and
there are no CSs available for handover, the PS may go out of range and the call could
be lost.
Example: Installing in a Room Separated by Walls
Things to take note of:
•
The room is separated by walls.
•
The room is surrounded by concrete walls.
CS installation plan:
•
The coverage area of each CS will not extend as much it does where there is no
obstacle, because the radio signals will be weakened by separating walls. Therefore,
you will need 5 CSs to cover the entire room.
70 m
150 m
CS no. 5
CS no. 1
CS no. 2
CS no. 4
CS no. 3
Summary of Contents for KX-T30865