9 Confirming the Status of Air Synchronization
for IP Cell Stations
After registering the IP-CS to the PBX, it is necessary to monitor the status of air synchronization for the IP-CS.
If the monitoring results are not satisfactory, relocate the IP-CS or change the IP-CS that it is currently
synchronized with to another CS using the Maintenance Console.
Monitoring Air Synchronization
The status of air synchronization for IP-CSs can be displayed and collected by the following procedure:
1.
From the
Utility
menu, select
CS Status Monitor
.
2.
From the
Interval Timer
drop-down list, select the desired interval time for monitoring.
3.
Click
Start
to monitor the status of air synchronization.
Note
For details about other parameters on this screen, refer to the PC Programming Manual or the On-line
Help for your PBX.
4.
Confirm the value in the
Monitored Level
column.
The monitored level is indicated as follows:
Monitored Level
Description
12
Up to 2 CSs: Good
More than 2 CSs: May be reset due to synchronization failure of CSs
09 to 11
Good
08
Better
07
Good
03 to 06
Air synchronization is established.
it is necessary to monitor the status of synchronization using the
Maintenance Console. This is necessary because IP-CSs may be
reset due to synchronization failure if the radio signal strength
fluctuates depending on changes in the installation environment such
as opening/closing doors.
Document Version 2009-12
Quick Installation Guide
53
9 Confirming the Status of Air Synchronization for IP Cell Stations