REG_INTERVAL_RATE_n
Parameter Name Example
REG_INTERVAL_RATE_1
,
REG_INTERVAL_RATE_2
, ...,
REG_INTERVAL_RATE_6
Value Format
INTEGER
Description
Specifies the percentage of the "expires" value after which to refresh
registration by sending a new REGISTER message in the same dialog.
Value Range
1–100
Default Value
50
REG_RTX_INTVL_n
Parameter Name Example
REG_RTX_INTVL_1
,
REG_RTX_INTVL_2
, ...,
REG_RTX_INTVL_6
Value Format
INTEGER
Description
Specifies the interval, in seconds, between transmissions of the
REGISTER request when a registration results in failure (server no
reply or error reply).
Value Range
1–86400
Default Value
10
USE_DEL_REG_OPEN_n
Parameter Name Example
USE_DEL_REG_OPEN_1
,
USE_DEL_REG_OPEN_2
, ...,
USE_DEL_REG_OPEN_6
Value Format
BOOLEAN
Description
Specifies whether to enable cancelation before registration when, for
example, the unit is turned on.
Value Range
•
Y
: Send un-REGISTER
•
N
: Does not send
Default Value
N
USE_DEL_REG_CLOSE_n
Parameter Name Example
USE_DEL_REG_CLOSE_1
,
USE_DEL_REG_CLOSE_2
, ...,
USE_DEL_REG_CLOSE_6
Value Format
BOOLEAN
Description
Specifies whether to enable the cancelation of registration before the
SIP function shuts down when, for example, the configuration has
changed.
248
Administrator Guide
Document Version 2015-07
5.3.22 SIP Settings