Value Range
•
Y
(Enable dial plan filtering)
•
N
(Disable dial plan filtering)
Note
•
If set to "
Y
", the dialed number will not be sent to the line when
the number dialed by the user does not match any of the dial
formats specified in the dial plan.
•
If set to "
N
", the dialed number will be sent to the line, even if
the number dialed by the user does not match any of the dial
formats specified in the dial plan.
Default Value
N
Web User Interface Reference
Call Even If Dial Plan Does Not Match (Page 128)
MACRODIGIT_TIM
Value Format
INTEGER
Description
Specifies the length of time, in seconds, that the unit waits when a "T"
or "t" has been entered in the dial plan.
Value Range
1–15
Default Value
5
Web User Interface Reference
Timer for Dial Plan (Page 120)
INTERNATIONAL_ACCESS_CODE
Value Format
STRING
Description
Specifies the number to be shown in the place of the first "+" symbol
when the phone number for incoming international calls contains "+".
Value Range
Max. 8 characters (consisting of 0–9, *, and #)
Note
•
No other characters are allowed.
Default Value
Empty string
Web User Interface Reference
International Call Prefix (Page 121)
COUNTRY_CALLING_CODE
Value Format
STRING
Description
Specifies the country/area calling code to be used for comparative
purposes when dialing a number from the incoming call log that
contains a "+" symbol.
Value Range
Max. 8 characters (consisting of 0–9)
258
Administrator Guide
Document Version 2015-02