![Panasonic KX-HDV100 Administrator'S Manual Download Page 209](http://html.mh-extra.com/html/panasonic/kx-hdv100/kx-hdv100_administrators-manual_269976209.webp)
REG_INTERVAL_RATE_n
Parameter Name Example
REG_INTERVAL_RATE_1
Value Format
INTEGER
Description
Specifies the percentage of the "expires" value after which to refresh
registration by sending a new REGISTER message in the same dialog.
Value Range
1–100
Default Value
50
REG_RTX_INTVL_n
Parameter Name Example
REG_RTX_INTVL_1
Value Format
INTEGER
Description
Specifies the interval, in seconds, between transmissions of the
REGISTER request when a registration results in failure (server no
reply or error reply).
Value Range
1–86400
Default Value
10
USE_DEL_REG_OPEN_n
Parameter Name Example
USE_DEL_REG_OPEN_1
Value Format
BOOLEAN
Description
Specifies whether to enable cancelation before registration when, for
example, the unit is turned on.
Value Range
•
Y
: Send un-REGISTER
•
N
: Does not send
Default Value
N
USE_DEL_REG_CLOSE_n
Parameter Name Example
USE_DEL_REG_CLOSE_1
Value Format
BOOLEAN
Description
Specifies whether to enable the cancelation of registration before the
SIP function shuts down when, for example, the configuration has
changed.
Value Range
•
Y
: Send un-REGISTER
•
N
: Does not send
Default Value
N
Document Version 2015-02
Administrator Guide
209
5.3.19 SIP Settings