![Panasonic KX-HDV100 Administrator'S Manual Download Page 236](http://html.mh-extra.com/html/panasonic/kx-hdv100/kx-hdv100_administrators-manual_269976236.webp)
VQREPORT_COLLECTOR_PORT
Value Format
INTEGER
Description
Specifies the port of the collector server.
Value Range
1–65535
Default Value
5060
Web User Interface Reference
VQREPORT_SEND
Value Format
INTEGER
Description
Specifies the sending type of the VQ report using PUBLISH.
Value Range
•
0: Disable
•
1: End of Session Report Using PUBLISH
•
2: Interval report Using PUBLISH
•
3: Alert Report Using PUBLISH
Default Value
0
Web User Interface Reference
ALERT_REPORT_TRIGGER
Value Format
INTEGER
Description
Specifies the trigger to notify the VQ report.
Value Range
•
0: Warning
•
1: Critical
Default Value
0
Web User Interface Reference
Alert Report Trigger (Page 113)
ALERT_REPORT_MOSQ_CRITICAL
Value Format
INTEGER
Description
Specifies the critical criteria to send VQ report at the time of occurring
the MOSQ.
Value Range
0–40
Default Value
0
Web User Interface Reference
Threshold MOS-LQ (Critical) (Page 113)
236
Administrator Guide
Document Version 2015-02
5.3.25 VQ Report by PUBLISH