12.3.2.1.5. The unit can copy, but cannot either transmit/receive long distance or interna-
tional communications
The following two causes can be considered for this symptom.
Cause 1:
The other party is executing automatic dialing, the call has been received by this unit, and the CED or DIS signal response time is
too long. (In most cases, this unit detects the CNG signal and can respond to CED or DIS.) (According to the ITU-T standard, the
communication procedure is cancelled when there is no response from the other party within 35 sec, so that the other party
releases the line.)
(Cause and Countermeasure)
As shown in the chart above, the total handshaking time must be reduced, but because of the long distance connection and link-
ing of several stations, the line connection time cannot be reduced. Accordingly, the following countermeasures should be tried.
(A)... As the 35 sec. count is started directly after dialing or directly after the START button has been pressed for models with a
START button, the other party should be called manually, if possible. Another possibility is entering two pauses at the end of the
auto dial number on the transmission side. Then the count start time can be delayed for 2 pauses (about 10 sec.).
Cause 2:
Erroneous detection because of an echo or an echo canceler.
(Echo/Echo Canceler)
The signal from FAX1 reaches FAX2 via stations 1 and 2, but the reflection signal at station 2 also returns via station 1 (echo).
As the distance between station 1 and station 2 is far, the echo returns to FAX 1 at a max of 600 msec after transmission. There
is a possibility that this signal is detected erroneously as the signal from FAX2. For a normal call, there is also a possibility that
the echo of their own voice will make the call difficult to understand. For this reason, each station (station 1 and station 2)
attaches echo cancelers (S1 and S2) for international lines or long distance lines. For the echo canceler, the level of the trans-
mission signal from FAX 1 is compared with the level of the reception signal from FAX2. When the transmission signal is larger,
S1 is closed while S2 is opened when it is smaller. In other words, for transmission from FAX1, S1 is closed and S2 is open, so
that the echo does not return to FAX1.
Summary of Contents for KX-FP701ME
Page 9: ...9 KX FP701ME 4 General Introduction 4 1 Error Message 4 1 1 Display 4 1 2 Report ...
Page 11: ...11 KX FP701ME 6 Technical Descriptions 6 1 Connection Diagram ...
Page 13: ...13 KX FP701ME 6 2 1 General Block Diagram ...
Page 15: ...15 KX FP701ME 6 3 2 Memory Map ...
Page 24: ...24 KX FP701ME 6 4 2 Block Diagram ...
Page 26: ...26 KX FP701ME ...
Page 68: ...68 KX FP701ME 11 2 2 Service Mode Settings Note The above values are the default values ...
Page 75: ...75 KX FP701ME Countermeasure ...
Page 76: ...76 KX FP701ME REFERENCE Test Mode P 60 ...
Page 77: ...77 KX FP701ME REFERENCE Test Mode P 60 ...
Page 78: ...78 KX FP701ME REFERENCE Test Mode P 60 ...
Page 79: ...79 KX FP701ME REFERENCE Test Mode P 60 ...
Page 80: ...80 KX FP701ME ...
Page 81: ...81 KX FP701ME ...
Page 82: ...82 KX FP701ME REFERENCE Test Mode P 60 ...
Page 86: ...86 KX FP701ME ...
Page 111: ...111 KX FP701ME ...
Page 118: ...118 KX FP701ME I O and Pin No Diagram ...
Page 120: ...120 KX FP701ME Other NG example while the power is ON and the LCD displays the following ...
Page 121: ...121 KX FP701ME 12 5 5 2 NG Example ...
Page 125: ...125 KX FP701ME 12 5 7 2 Troubleshooting Flow Chart ...
Page 129: ...129 KX FP701ME 12 5 9 5 Check the HOOK Switch SW101 ...
Page 131: ...131 KX FP701ME 12 5 11 Thermal Head Section Note Refer to Thermal Head P 25 ...
Page 132: ...132 KX FP701ME 13 Service Fixture Tools ...
Page 136: ...136 KX FP701ME 14 2 2 HOW TO REMOVE THE OPERATION PANEL BLOCK ...
Page 137: ...137 KX FP701ME 14 2 3 HOW TO REMOVE THE OPERATION BOARD AND LCD ...
Page 138: ...138 KX FP701ME 14 2 4 HOW TO REMOVE THE SEPARATION HOLDER AND EXIT ROLLER ...
Page 139: ...139 KX FP701ME 14 2 5 HOW TO REMOVE THE IMAGE SENSOR CIS ...
Page 140: ...140 KX FP701ME 14 2 6 HOW TO REMOVE THE THERMAL HEAD ...
Page 141: ...141 KX FP701ME 14 2 7 HOW TO REMOVE THE PLATEN ROLLER AND BACK COVER ...
Page 142: ...142 KX FP701ME 14 2 8 HOW TO REMOVE THE PICKUP ROLLER ...
Page 143: ...143 KX FP701ME 14 2 9 HOW TO REMOVE THE CASSETTE LEVER ...
Page 144: ...144 KX FP701ME 14 2 10 HOW TO REMOVE THE BOTTOM FRAME ...
Page 145: ...145 KX FP701ME 14 2 11 HOW TO REMOVE THE DIGITAL ANALOG SENSOR BOARDS ...
Page 146: ...146 KX FP701ME 14 2 12 HOW TO REMOVE THE POWER SUPPLY BOARD AND AC CORD ...
Page 147: ...147 KX FP701ME 14 2 13 HOW TO REMOVE THE MOTOR BLOCK AND SEPARATION ROLLER ...
Page 148: ...148 KX FP701ME 14 2 14 HOW TO REMOVE THE GEARS OF MOTOR BLOCK ...
Page 149: ...149 KX FP701ME 14 2 15 INSTALLATION POSITION OF THE LEAD WIRES ...
Page 163: ...163 KX FP701ME 16 1 4 Power Supply Board 16 1 5 Interface Board ...
Page 166: ...166 KX FP701ME 16 3 Test Chart 16 3 1 ITU T No 1 Test chart ...
Page 167: ...167 KX FP701ME 16 3 2 ITU T No 2 Test Chart ...
Page 168: ...168 KX FP701ME 16 3 3 Test Chart ...
Page 169: ...169 KX FP701ME MEMO ...
Page 180: ...180 KX FP701ME MEMO ...
Page 188: ...188 KX FP701ME MEMO ...
Page 194: ...194 KX FP701ME 20 1 2 Operation Panel Section ...
Page 195: ...195 KX FP701ME 20 1 3 Back Cover Section ...
Page 196: ...196 KX FP701ME ...
Page 197: ...197 KX FP701ME 20 1 4 Upper Cabinet Section ...
Page 198: ...198 KX FP701ME 20 1 5 Lower Cabinet Section ...
Page 199: ...199 KX FP701ME 20 1 6 Gear Block Section ...
Page 200: ...200 KX FP701ME 20 1 7 Screws ...
Page 201: ...201 KX FP701ME 20 1 8 Accessories and Packing Materials ...